GATE AG 2015 • Q16 MCQ • 1 Mark

Section 3: Farm Power

Farm Power

Subtopic: Thermodynamic principles of I.C. engines

Question Statement:

Discharge through an irrigation outlet is independent of the water levels in the distributary and water courses in case of

Options:

  • (A) non-modular outlet
  • (B) semi-modular outlet
  • (C) Kennedy's gauge outlet
  • (D) Gibb's module outlet

Official Answer Key:

D

Step-by-Step Solution & Explanation

A rigid (fully) modular outlet, such as Gibb's module, delivers a discharge that is independent of both the water level in the distributary channel (upstream) and the water level in the watercourse (downstream) — that is precisely the definition of a rigid module. A non-modular outlet (A) depends on both water levels; a semi-modular (flexible module) outlet (B), such as a pipe outlet or orifice-type semi-module, depends on the upstream (distributary) water level only, not the downstream one. ‘Kennedy's gauge outlet’ (C) is not a standard rigid-module outlet type. Hence (D) Gibb's module outlet is correct.

Practice This in Real CBT Exam Interface

Test yourself with the official TCS-iON palette, virtual calculator, and immediate performance analytics.

Launch CBT Mock Test